correlospinmatrix_detector – Device for measuring the covariance matrix from several inputs¶
Description¶
The correlospinmatrix_detector
is a recording device. It is used
to record correlations from binary neurons from several binary sources and
calculates the raw auto and cross correlation binned to bins of duration
delta_tau
. The result can be obtained via GetStatus`()
under the key
/count_covariance
. The result is a tensor of rank 3 of size
N_channels x N_channels
, with each entry \(C_{ij}\) being a vector of size
\(2\cdot\tau_{max}/\delta_{\tau} + 1\) containing the histogram for the
different time lags.
The bins are centered around the time difference they represent, and are left-closed and right-open in the lower triangular part of the matrix. On the diagonal and in the upper triangular part the intervals are left-open and right-closed. This ensures proper counting of events at the border of bins.
The correlospinmatrix_detector
has a variable number of inputs which can be
set via SetStatus under the key N_channels. All incoming connections to a
specified receptor will be pooled.
Setting either N_channels, Tstart, Tstop, tau_max or delta_tau clears count_covariance.
Correlospinmatrix detectors ignore any connection delays.
See Correlospinmatrix detector example for a script reproducing a setting studied in Fig 1 of Grinzburg & Sompolinsky (1994) PRE 50(4) p. 3171.
Parameters¶
Tstart |
real |
Time when to start counting events. This time should be set to at least start + tau_max in order to avoid edge effects of the correlation counts. |
Tstop |
real |
Time when to stop counting events. This time should be set to at most Tsim - tau_max, where Tsim is the duration of simulation, in order to avoid edge effects of the correlation counts. |
delta_tau |
ms |
Bin width. This has to be an odd multiple of the resolution, to allow the symmetry between positive and negative time-lags. |
tau_max |
ms |
One-sided width. In the lower triagnular part events with differences in [0, tau_max+delta_tau/2) are counted. On the diagonal and in the upper triangular part events with differences in (0, tau_max+delta_tau/2]. |
N_channels |
integer |
The number of pools. This defines the range of receptor_type. Default is 1. Setting N_channels clears count_covariance, covariance and n_events. |
covariance |
3D matrix of integers |
matrix of read-only -raw, weighted, auto/cross correlation |
count_covariance |
3D matrix of integers |
matrix of read-only -raw, auto/cross correlation counts |
Receives¶
SpikeEvent